Troubleshooting
No Hot Water: Common Causes and What to Check
No hot water is one of the most common plumbing calls in Ireland. Before calling a plumber, work through these checks, some causes are simple fixes you can do yourself.
No hot water
No hot water is one of the most common plumbing calls in Ireland. Before you ring a plumber, a few quick checks often point to the cause, and some are simple fixes you can do yourself.
Start with the boiler display, as most modern boilers show a fault code when something is wrong. From there, check the system pressure and the programmer or timer, since a power cut or a knocked schedule is a frequent culprit. Homes with a hot water cylinder have a few extra parts that can fail, such as the cylinder thermostat or a stuck motorised valve. If the fault does not clear or you smell gas, that is the point to call an RGI-registered gas engineer.

What to check first
No Hot Water: What to Check First
Look at the boiler display or indicator lights first. Most modern boilers show a fault code when there is a problem, so note the code and look it up in your boiler manual or against your boiler brand name. Common codes relate to low pressure, ignition failure, or a sensor fault. A reset (usually a button on the front panel) sometimes clears a temporary fault, but if the same code returns within an hour there is an underlying issue for a plumber or gas engineer.
Then check the boiler pressure. Most combi and system boilers need 1 to 1.5 bar to fire, and if the gauge sits in the red zone the boiler locks out. To repressurise, open both valves on the filling loop slowly until the gauge reads 1 to 1.5 bar, then close them firmly. Finally, check the programmer or timer, as a power cut or a knocked schedule can leave hot water switched off for the current time period.
- Check the boiler display for a fault code
- Check boiler pressure and aim for 1 to 1.5 bar
- Check the programmer and timer settings
- Try a boiler reset once
- Switch on the immersion as a backup
Why it happens
Common Causes of No Hot Water in Ireland
Knowing the usual culprits helps you check the easy things first and describe the fault clearly when you call.
Boiler Fault Code
A code for ignition failure or a sensor fault can stop the boiler firing. Note the code and try one reset; if it returns within an hour, it needs a plumber or gas engineer.
Low System Pressure
Combi and system boilers need 1 to 1.5 bar to fire. If the gauge sits in the red zone the boiler locks out, and repeated drops point to a leak in the system.
Timer or Programmer
A power cut can reset the programmer, or a smart thermostat schedule may have hot water set to off. Check hot water is enabled for the current time period.
Cylinder Thermostat
In homes with a hot water cylinder, a failed cylinder thermostat leaves the water cold even when the boiler is working normally.
Stuck Motorised Valve
The motorised valve directs hot water to the cylinder. If it sticks, the boiler can run for heating while the hot water stays cold.
Immersion Not On
The immersion heater is a backup for cylinder homes. If the boiler is down and the immersion is off, there is no other source of stored hot water.
Typical costs
What No Hot Water Repairs Cost in 2026
Costs depend on which part has failed and whether it is a simple reset, a component swap, or a boiler repair. Ask for the call-out charge and a written quote before any work begins.
- Ask for the call-out charge before a plumber comes out
- An annual boiler service helps prevent no hot water breakdowns
- Get a written quote and keep the invoice
Indicative 2026 ranges including labour. Gas appliances must be serviced by an RGI-registered gas engineer, so never open the boiler casing yourself.
- Boiler service €80–120
- Cylinder thermostat €100–180
- Motorised valve replacement €150–280
- Boiler repair (parts vary) €150–400
Indicative 2026 ranges. Always confirm with the plumber before work begins.
Cylinder or combi
Cylinder, Immersion or Combi
Homes with a system boiler or back boiler store hot water in a cylinder, usually in the hot press. If the boiler is running but the water stays cold, the cylinder thermostat may have failed, or the motorised valve that sends hot water to the cylinder may be stuck. You can switch the immersion heater on for about 45 minutes as a temporary backup: if hot water returns, the fault is with the boiler or its controls, not the cylinder itself.
A combi boiler heats water on demand and has no cylinder, so there is nothing stored to reheat. With a combi, no hot water usually points back to the boiler, its pressure, or the programmer rather than a separate hot water circuit. Knowing which type you have narrows down where the fault is likely to be before a plumber calls out.

Browse by county
Find a Plumber in Your County
Every plumber listed is contactable directly for boiler and hot water faults, county by county across Ireland.
Leinster
12 countiesDublin and the east, where combi boilers and older cylinders both feature across city and suburb.
Munster
6 countiesCork, Limerick and the south west, from urban terraces to rural homes on oil and gas.
Connacht
5 countiesGalway, Mayo and the west, where system boilers with hot press cylinders are common.
Common questions
No Hot Water: Common Questions
Why do I have no hot water but the heating works?
In a home with a hot water cylinder, this usually points to a failed cylinder thermostat or a stuck motorised valve, which is the part that directs hot water to the cylinder. The boiler can keep running for the heating circuit while the hot water stays cold. A plumber can test both and replace whichever has failed.
How do I repressurise my boiler?
Most combi and system boilers need 1 to 1.5 bar to operate. Locate the filling loop, a flexible braided hose under the boiler, open both valves slowly until the gauge reads 1 to 1.5 bar, then close both valves firmly. If the pressure drops again within a few days, there is a leak in the system that needs to be found and fixed.
Can I use the immersion heater as a backup?
Yes, if you have a hot water cylinder. Switch the immersion on and wait about 45 minutes. If hot water returns, the boiler or its controls are the issue rather than the cylinder itself, which is useful to know before a plumber calls out.
Should I open the boiler myself if there is a fault?
No. Do not open the boiler casing yourself, as gas appliances must be serviced by an RGI-registered gas engineer. If you smell gas near the boiler, call Gas Networks Ireland on 1800 20 50 50 first. An annual boiler service is the best way to prevent no hot water emergencies.
Still No Hot Water? Find a Plumber
If the checks have not fixed it, get an RGI-registered plumber out. Browse plumbers across Ireland and call them directly.
Find a plumber